Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1881 PID: SID 324 SPN: 3251 FMI: 4 Aftertreatment Diesel Particulate Filter Differential Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit Description
The electronic control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter differential pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter differential pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter differential pressure sensor signal circuit. This sensor signal voltage changes, based on the differential pressure across the aftertreatment diesel particulate filter.

Component Location
The aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault Codes
The ECM detects that the aftertreatment diesel particulate filter differential pressure signal voltage is less than 0.25-VDC for more than 2 seconds.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
A default value of the aftertreatment diesel particulate filter differential pressure is used.
Diesel exhaust fluid injection into the aftertreatment system is disabled.
Active and stationary regeneration of the diesel particulate filter will be disabled.
The EGR valve will be closed.
Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.
Conditions for Clearing the Fault Code
To validate the repair, start the engine and let it idle for 1 minute.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.
For On-Board Diagnostic (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The Reset All Faults command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk
Possible causes of this fault code include:

Signal circuit open or shorted to ground in the OEM harness or sensor
Supply line open or shorted to ground.
Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:
1) OEM harness
2) ECM calibration