Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Cummins ISX12 CM2250 (2010-12) Fault Code: 132 PID: 91 SPN: 91 FMI: 4 Accelerator Pedal or Lever Position Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit Description
The accelerator position sensor is a Hall effect sensor attached to the accelerator pedal. The accelerator position sensor varies the signal voltage to the electronic control module (ECM) as the accelerator pedal is depressed and released. Low signal voltage is received by the ECM when the accelerator pedal is at 0 percent. A high signal voltage is received by the ECM when the accelerator pedal is at 100 percent. The accelerator pedal position circuit contains an accelerator pedal position 5 volt supply, accelerator pedal position return, and accelerator pedal position signal.

The accelerator pedal contains two position sensors. These position sensors are used to measure the throttle position. Both position sensors receive a 5 volt supply from the ECM. A corresponding signal voltage based on the position of the accelerator pedal is then received from the ECM. The signal voltage for accelerator position 1 is twice as much as the signal voltage for the accelerator position 2.

When the ECM senses a signal voltage lower than the normal operating range of the sensor, this fault code is set.

Component Location
The accelerator pedal or lever position sensor is mounted to the accelerator pedal assembly. Refer to the OEM service manual.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position.

Conditions for Setting the Fault Codes
The ECM detects that the throttle pedal signal voltage is less than 0.826-VDC for more than 1 second.

Action Taken When the Fault Code is Active
The ECM illuminates the red STOP ENGINE light and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
To validate the repair, start the engine and let it idle for 1 minute.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ECM will turn off the red STOP ENGINE light immediately after the diagnostic runs and passes.
For OBD engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The ?Reset All Faults? command in the INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD engines.

Shop Talk
Newer engines use two throttle position sensors to determine the throttle position. Older throttle pedals used a single throttle position sensor and an idle validation switch. If Fault Codes 132 and 1241 are active when the accelerator pedal is in the idle position and Fault Code 132 goes inactive and Fault Code 1239 goes active when the throttle is depressed, the incorrect throttle pedal has been installed in the vehicle. A throttle pedal with two acceleration position sensors must be installed. If troubleshooting an intermittent accelerator problem:

The accelerator pedal or lever position sensor signal voltage can be monitored with INSITE? electronic service tool, while flexing the harness to locate the intermittent connection. Intermittent connections will show up as abrupt changes in signal voltage displayed by INSITE? electronic service tool.

Possible causes of this fault include:

Accelerator pedal or lever position signal shorted to engine ground or return wires in the OEM harness or sensor
Damaged accelerator pedal or lever position sensor
Open circuit in the accelerator signal, supply, or return wire in the harness or connectors.
NOTE: The three wires in the accelerator position sensor circuit must be twisted together.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:
1) OEM harness
2) ECM failure