Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3509 FMI 4 (MCM) 5V Sensor Supply Bank 1 Circuit Failed Low

DESCRIPTION:
This fault sets when the Motor Control Module (MCM) detects a short to ground on the bank one sensor voltage supply (Pins 58 or 117..

MONITORED PARAMETER:
5V internal power supply.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Engine Idle: One minute.

PROBABLE CAUSES:
Short to power from the MCM pins to a sensor:
1. Pin 58, charge air cooler outlet pressure sensor.
2. Pin 102, charge air cooler pressure sensor.