Detroit DD15 EPA10 (2010-13) Fault Code: SPN 411 FMI 4 (MCM) EGR Delta Pressure Sensor Circuit Failed Low

DESCRIPTION:
This fault code sets when there is an open in the voltage supply circuit, an open or short to ground on the signal return circuit.

MONITORED PARAMETER:
EGR delta pressure sensor return signal.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
2 seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 25%

VERIFICATION:
Engine Idle: One minute.

PROBABLE CAUSES:
1. EGR delta p sensor failure.
2. EGR delta p connector/harness.
3. EGR delta p pressure ports blocked.
4. EGR valve failure.
5. Inspect the EGR crossover tube and mixer pipe for excessive buildup. If excessive, replaced the EGR cooler.
6. Inspect EGR system for leaks/damage/issues.