Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low

DESCRIPTION:
Accelerator pedal sensor failed low.

MONITORED PARAMETER:
Pedal supply voltage.

TYPICAL ENABLING CONDITIONS:
Always on

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
CEL

ENGINE REACTION:
None

VERIFICATION:
Key cycle: Ignition on.

NOTE: Disconnect one sensor at a time.

PROBABLE CAUSES:
When code goes inactive, that is the sensor that has failed:
1. Fuel line pressure sensor.
2. Fuel compensation pressure sensor.
3. Engine oil pressure sensor.
4. Inlet manifold pressure/temperature sensor.
5. DPF inlet pressure sensor.
6. DPF outlet pressure sensor.
7. Intake throttle valve.
8. Camshaft position sensor.

NOTE: If none go inactive, disconnect the 31-pin connector on left side of the engine. If code goes inactive, replace the DPF pressure sensor.

NOTE: If you disconnect the 120-pin ECM connection and the code is still active, replace the MCM.