PACCAR PX-8 CM2150 (2007-09) Fault Code: 252 PID: 98 SPN: 98 FMI: 2 Engine Oil Level – Data Erratic, Intermittent, or Incorrect. An intermittent signal is being received from the oil level sensor.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
Possible causes:
1)The oil level sensor is not receiving power from the ECM. This could be caused by an open circuit in the power supply or low voltage supplied by the primary engine ECM
2)Open return circuit on the oil level sensor circuit between the engine ECM and the oil level sensor
3)Open or short circuit on the oil level sensor signal circuit between the ECM and oil level sensor
4)A damaged oil level sensor.
Possible repairs:
1)Repair or replace the engine harness.
2)Replace the ECM.
3)Replace the oil level sensor.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00