Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Cummins ISC CM2150 (2007-09) Fault Code: 2367 PID: SID 80 SPN: 1073 FMI: 3 Engine Brake Actuator Driver Output 2 Circuit – Voltage Above Normal or Shorted to High Source. Open circuit or high voltage detected at the engine brake solenoid number 2 signal circuit.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

Possible causes:

1)Open circuit in the engine harness, brake harness, or engine brake solenoids
2)Short to voltage source in the engine harness
3)Damaged ECM.

Possible repairs:

1)Replace the engine brake solenoid.
2)Replace the ECM.
3)Repair or replace the engine harness.