Cummins ISC CM2150 (2007-09) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 3 circuit.

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

High voltage on the (+) 5 volt supply wire can be caused by a short to battery voltage in the engine harness or connectors, or a damaged ECM.

Possible repairs:

1)Replace the ECM.
2)Repair or replace the engine harness.Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.

High voltage on the (+) 5 volt supply wire can be caused by a short to battery voltage in the engine harness or connectors, or a damaged ECM.

Possible repairs:

1)Replace the ECM.
2)Repair or replace the engine harness.