Cummins ISX12 CM2250 (2010-12) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit Description
The exhaust gas temperature is calculated by the ECM. The exhaust gas temperature is derived by the ECM, based on engine operating conditions, such as intake manifold air temperature, engine speed, injection timing, intake manifold pressure, and fuel flow.

Component Location
There is not a physical exhaust gas temperature sensor in the system. The exhaust gas temperature is a calculation of exhaust gas temperature before the turbocharger, and is also known as turbine inlet temperature.

NOTE: Some original equipment manufacturers (OEMs) have pyrometer gauges mounted in their chassis. Pyrometers measure turbine outlet temperature or the exhaust gas temperature leaving the turbocharger and will not equal the value monitored with the exhaust gas temperature parameter with INSITE? electronic service tool.

Conditions for Running the Diagnostics
This diagnostic runs continuously when the engine is operating.

Conditions for Setting the Fault Codes
The ECM detects that the calculated turbine inlet temperature is greater than a calibratible value.

Action Taken When the Fault Code is Active
The ECM logs the fault code immediately when the temperature threshold is exceeded.
Fuel is limited in an attempt to decrease the exhaust gas temperature entering the turbocharger.
Conditions for Clearing the Fault Code
To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop-and-go city driving and steady state highway driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.
To validate the repair using a Chassis Dynamometer Test, utilize a routine that incorporates acceleration and motoring events, steady state highway operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.
The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults.

Shop Talk
The most common cause of this fault code is low boost pressure. Low boost pressure can be caused by several factors: leaking charge-air cooler, damaged charge-air cooler piping or hose, loose charge-air cooler clamps, damaged intake manifold pressure sensor, damaged variable geometry turbocharger, damaged turbocharger control valve, or damaged turbocharger control shutoff valve.

This fault code can also be caused by a turbocharger fuel control derate, which can be viewed with INSITE? electronic service tool, under the Engine Operating State. Turbocharger fuel control derates can be caused by several factors: high exhaust temperatures, turbocharger compressor inlet temperatures, and turbocharger compressor outlet temperatures.

Exhaust gas recirculation (EGR) system leaks can also cause this fault code. Inspect the EGR bellows and EGR connections for signs of leaks.

NOTE: This fault code will most likely not be active with no load in the shop. The engine must be loaded to trip this fault code, and to determine if the cause has been found and repaired. Operating units on the dynamometer can sometimes cause this fault code to log, due to the stationary nature and high temperatures.

Possible Cause:
1) ECM calibration