Cummins ISM CM870 (2003-06) Fault Code: 432 PID: S230 SPN: 558 FMI: 13/13 Accelerator Pedal Idle Validation Circuit – out of calibration. Voltage at idle validation on-idle and off-idle circuit does not match accelerator pedal position.
This fault is logged when both the on idle and off idle validation switches disagree with the accelerator pedal position signal. Turning the keyswitch ON while partially depressing the accelerator pedal can cause this fault code to go active. This fault will stay active until the pedal is cycled through its full travel.
Possible repairs:
1)Replace the accelerator pedal assembly.
2)Replace the OEM harness.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00