Cummins ISM CM875 (2003-06) Fault Code: 2272 PID: P27 SPN: 27 FMI: 4/4 Exhaust Gas Recirculation (EGR) Valve Position Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at EGR valve position sensor circuit.
The EGR valve position sensor shares supply and return wires in the engine harness with other sensors. Open circuits and shorts circuits in the engine harness can cause multiple fault codes to be active.
Possible causes:
1)Signal circuit open or shorted to ground
2)Supply circuit open or shorted to ground
3)Sensor shorted to ground
4)Damaged EGR valve.
Possible repairs:
1)Replace the EGR valve assembly.
2)Replace the ECM.
3)Repair or replace the appropriate harness.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00