Cummins ISX CM870 (2003-06) Fault Code: 132 PID: P091 SPN: 91 FMI: 4/4 Accelerator Pedal or Lever Position Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at accelerator pedal position number 1 signal circuit
Possible causes:
1)Accelerator pedal or lever position signal shorted to engine ground or return wires in the OEM harness or sensor
2)Damaged accelerator pedal or lever position sensor
3)Open circuit in the accelerator signal, supply, or return wire in the harness or connectors.
NOTE: The three wires in the accelerator position sensor circuit must be twisted together
Possible repair:
1)Repair the damaged harness, connector, or pins, if possible.
2)Repair or replace the OEM wiring harness.
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00