Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4360 FMI 8 (ACM) SCR Inlet Temperature Signal Spike

DESCRIPTION:
This fault code sets when the Aftertreatment Control Module (ACM) detects a momentary abnormal Selective Catalyst Reduction (SCR) inlet temperature reading.

MONITORED PARAMETER:
Selective Catalyst Reduction Inlet Temperature sensor.

TYPICAL ENABLING CONDITIONS:
Non-Regen Mode

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
SCR efficiency test.

NOTE: This fault indicates that the ACM has detected a sudden temperature switch on the SCR outlet temperature sensor. Most likely cause is wiring failure.

NOTE: If codes 4360-3 or 4360-4 are active, fix those first.

PROBABLE CAUSES:
1. Check all SCR sensor wiring for looseness, breaks, rubs, etc…
2. SCR outlet temperature sensor failure.