Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3509 FMI 4 (MCM) 5V Sensor Supply Bank 1 Circuit Failed Low
DESCRIPTION:
This code sets when the motor control module (MCM) detects a short to ground on pins 58 or 117.
MONITORED PARAMETER:
5V internal power supply.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
None
VERIFICATION:
Engine Idle: One minute.
PROBABLE CAUSES:
Short to power from the MCM pins to a sensor:
1. Pin 58, charge air cooler outlet pressure sensor.
2. Pin 102, charge air cooler pressure sensor.