Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3511 FMI 4 (CPC) Remote Accelerator Pedal Supply Voltage Circuit Failed Low
NOTE: This code sets when the common powertrain controller (CPC) detects the voltage on the sensor supply circuits is out of range.
DESCRIPTION:
Remote accelerator pedal supply voltage circuit failed low.
MONITORED PARAMETER:
Remote accelerator pedal voltage.
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
Key on
EXECUTION FREQUENCY:
None
TYPICAL DURATION:
None
DASH LAMPS:
CEL
ENGINE REACTION:
Idle only
VERIFICATION:
1. Ignition key
2. Cycle on
POSSIBLE CAUSES:
1. Remote accelerator pedal assembly.
2. Circuit fault.
3. Fault within the CPC.
4. Improper configuration of the CPC.
NOTE: This code always indicates to replace the MCM.
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00