Detroit DD15 EPA10 (2010-13) Fault Code: SPN 1071 FMI 3 (MCM, CPC) Fan Stage 2 Circuit Failed High
DESCRIPTION:
Fan circuit failed high.
MONITORED PARAMETER:
Fan control solenoid.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
2 seconds
DASH LAMPS:
None
ENGINE REACTION:
None
VERIFICATION:
Ignition cycle
PROBABLE FAILURES:
1. Fan control solenoid connector/harness.
2. Fan control solenoid failure.
-