Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3361 FMI 7 (ACM) Diesel Exhaust Fluid Metering Unit – Unable to Clear Restriction
DESCRIPTION:
Diesel exhaust fluid (DEF) unit – unable to clear restriction.
MONITORED PARAMETER:
1. DEF pressure.
2. DEF air pressure.
TYPICAL ENABLING CONDITIONS:
Dosing enabled
MONITOR SEQUENCE:
SPN 4335/14 and 31 active.
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Selective catalyst reduction (SCR) quantity test.
PROBABLE CAUSES:
1. Failed DEF pressure sensor.
2. DEF metering unit air inlet restricted.
3. Flush the DEF system.
4. Failed diffuser heater.
5. Failed DEF nozzle.
6. Failed supply hose for DEF.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00
-
SERVICE MANUAL 3000 AND 4000 SERIES GEN 4 GENERATION – ALLISON
Allison$19.00Original price was: $19.00.$17.00Current price is: $17.00.