Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4193 FMI 3 (MCM) Engine Coolant Inlet Temperature Circuit Failed High
DESCRIPTION:
Engine coolant inlet temperature circuit failed high.
MONITORED PARAMETER:
Engine coolant inlet temperature sensor.
TYPICAL ENABLING CONDITIONS:
Always enabled
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Always enabled
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
VERIFICATION:
Engine Idle: One minute.
NOTE: If there are any cooling system faults or conditions, repair those first.
PROBABLE CAUSES:
1. Inlet coolant temperature sensor.
1. Inlet coolant temperature sensor connector/harness.