Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1077 FMI 4 (MCM) Quantity Control Valve (QCV) Circuit Failed Low
DESCRIPTION:
Quantity control valve (QCV) circuit failed low.
MONITORED PARAMETER:
Quantity control valve (QCV) circuit.
TYPICAL ENABLING CONDITIONS:
Always on
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Parked regen
PROBABLE CAUSES:
1. Quantity control valve connector/harness.
2. Quantity control valve.