Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 751 FMI: 2 Invalid Shift Lever Voltage: Data Erratic

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device with a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the shift device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever.

Fault Code 14 indicates the TECU has detected an electrical fault in either the OEM-supplied wiring or Shift Control Device.

Detection:
TECU monitors the voltage from the analog Shift Control Device. Fault Code 14 sets when the reported voltage for a selected mode does not match the actual value for that lever position.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU receives erratic gear position information from the Shift Lever.

Fallback (All FMIs):
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission is limited to down shifts only.
• Transmission may not engage a gear from neutral.
• If a fault occurs with the manual mode up or down buttons, manual mode can not be used. The transmission will shift as normal in auto mode.

Conditions to Set Fault Code Inactive:
All FMIs: Signal voltage enters a valid range for 0.2 seconds.

Possible Causes:
1) Vehicle Harness – Excessive resistance in shifter wiring – Bent, spread, corroded or loose terminals
2) Analog Shift Lever – Internal failure