Eaton Gen 1 (AutoShift) Fault Code: 63 PID: SID 40 FMI: 6 Gear Select Motor
Overview:
This code indicates an electrical failure of the gear select motor that drives the electric shifter.
Detection:
Starting at key-on and throughout operation, the Transmission Controller constantly measures the motor circuit. Failure mode of short to battery, short to ground, or open circuit is detected. The Transmission Controller also monitors the amount of current required to drive the motors. If the over current limit is exceeded, the fault code is also set.
Fallback:
This fault causes an In Place fallback.
Required Tools:
1) Basic Hand Tools
2) Digital Volt/Ohm Meter
3) AutoSelect/AutoShift Troubleshooting Guide
Possible Causes:
1) Failed gear select motor
2) Malfunctioning transmission ECU