Eaton Gen 1 (AutoShift) Fault Code: 74 PID: SID 54 FMI: 7 Failed To Sync Initial Engagement
Overview:
This code indicates the system was unable to bring input shaft to a stop using the interia brake.
Detection:
The System Manager monitors engine rpm before initial gear engagement. If the inertia brake is commanded on and the engine rpm does not drop below the acceptable limit this code will be set.
Fallback
There is no fallback mode for this fault.
Required Tools:
1) Basic Hand Tools
2) Hand-Held Diagnostic Tool
3) 0-100 PSI Air Pressure Gauges
4) AutoSelect/AutoShift Troubleshooting Guide
Possible Causes:
1) Low air pressure
2) Contaminated air supply
3) Clutch out of adjustment
4) Damaged input shaft brake
5) Malfunctioning inertia brake
6) Damaged internal transmission gearing
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00