PACCAR PX-6 CM2150 (2007-09) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit – Voltage Above Normal or Shorted to High Source. Open circuit or high voltage detected at starter lockout circuit.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on Quickserve® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
The ECM monitors the voltage level on this circuit. If it detects a voltage when the signal is commanded off, it records this fault code.
Possible causes:
1)Open circuit in the starter lockout relay, OEM harness, or connectors
2)Short circuit to a voltage source in the OEM harness or relay.
Possible repairs:
1)Replace the starter lockout relay.
2)Clean, repair, or replace the OEM harness.
3)Repair or replace the OEM harness.
4)Replace the ECM.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: P0870 Transmission Pressure Switch Solenoid E Circuit
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00