PACCAR PX-8 CM2150 (2007-09) Fault Code: 154 PID: 105 SPN: 105 FMI: 4 Intake Manifold 1 Temperature Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at intake manifold air temperature circuit.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
The intake manifold temperature sensor shares return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Check fault codes with multiple counts first.
Possible causes:
1)Signal circuit shorted to ground in the harness
2)Signal circuit shorted to return or ground in the sensor.
Possible repairs:
1)Replace the intake manifold air temperature sensor.
2)Replace the ECM.
3)Repair or replace the engine harness.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00