Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A14.EB:27 is more than 4.92?V
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) High fuel consumption
2) The engine coolant temperature (ECT) gauge shows 0
3) Engine fan constantly engaged
Probable cause
1) Connector
2) Wiring harness
3) Engine coolant temperature sensor
4) Engine Control Module
-
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
Related products
-
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 171 FMI 14 (CPC) J1587 Ambient Air Temperature Sensor Data Not Received this Ignition Cycle
DD16 EPA07 (2007-09)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P1351 VTG Turbocharger Actuator – Internal Error
MX (2004 Emissions)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P20C000 PID: ACM Aftertreatment Reagent Hose Heater 2 Short Circuit High
All Engines (2013 Emissions)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P2541 Fuel Pressure – Voltage Too Low or Short Circuit to Ground on ECU (D420) Pin (A50)
MX (2004 Emissions)Rated 0 out of 5 -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 4353 FMI 5 (ACM) Diffuser Heater Open Circuit
DD16 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 84 FMI 3 (MCM) Vehicle Speed Sensor Open Circuit
DD15 EPA10 (2010-13)Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: U2104 CAN Bus Reset Counter Overrun
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0756 Shift Solenoid 2 (SS2) Valve Performance – Stuck Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P115800 PID: EMS Reductant Control Module Sensor Power Supply “A” Circuit High
All Engines (2013 Emissions)Rated 0 out of 5