Voltage from the engine control module (ECM) is applied to the engine coolant level (ECL) switch when the ignition switch is in the ON position. When the reservoir runs low, the float will be lowered on the coolant level sensor. The signal to the ECM will indicate low coolant.
If the engine control module (ECM) detects that the coolant level switch has experienced a power loss or that the level can not be detected, the ECM will set a diagnostic trouble code (DTC) and derate the engine to avoid engine damage.
Conditions for diagnostic trouble code (DTC):
1) Coolant Critically low level
Observable symptoms
1) Power loss
2) High derate with potentional engine shutdown
Probable cause
1) Low coolant level
2) The sensor float is stuck
3) Connector
4) Wiring harness
5) Engine Coolant Level (ECL) Sensor
6) Engine control module (ECM)
-
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5
Related products
-
Volvo All Engines (2017 Emissions) Fault Code: P110286 PID: EMS Reductant Pump “A” Control Circuit Electrical
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3696 FMI 9 (CPC) Diesel Particulate Filter Regen Force MUX Switch Message Stopped Arriving
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 120 FMI 13 (CPC) Retarder Fluid Message is Missing or Not Available
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P269773 PID: EMS Exhaust Aftertreatment Fuel Injector “A”
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 710 FMI 3 (MCM) Digital Output 4 06 Circuit Failed High
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 723 FMI 10 (MCM) Camshaft Position (CMP) Sensor Signal Erratic
DD15 EPA07 (2007-09)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P25AE00 PID: EMS Piston Cooling Oil Pressure Too Low
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 157 FMI 10 (MCM) Under-Capacity in the High Pressure Circuit
DD15 GHG14 (2014-16)Rated 0 out of 5