Aftertreatment Diesel Exhaust Fluid (DEF) Tank, Level Sensor has an indicator lamp and gauge in the instrument cluster. A solid lamp comes on when there is approximately 16% DEF remaining in the tank. A flashing lamp indicates when there is approximately 4% DEF remaining in the tank. A 25% engine derate is possible if the DEF is not refilled above the red line on the gauge at the next engine start up.
Conditions for diagnostic trouble code (DTC):
1) Short circuit to ground in the component or wiring
2) Short circuit to lower voltage
Observable symptoms
1) The Aftertreatment diesel exhaust fluid (DEF) tank level gauge remains permanently at the minimum level
Probable cause
1) Connector
2) Wiring harness
3) Short circuit to ground
4) Aftertreatment diesel exhaust fluid (DEF) tank, Level Sensor
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00 -
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00
Related products
-
Allison 3000 & 4000 Gen 4 Fault Code: P0882 TCM Power Input Signal Low
3000 & 4000 Gen 4 -
Volvo All Engines (2013 Emissions) Fault Code: P027300 PID: EMS Cylinder 5 Injector Circuit Low
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P018564 PID: EMS Fuel Temperature Sensor “B”
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P111900 PID: EMS Intake Manifold Temperature Moderately Too High
All Engines (2013 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 94 FMI 3 PID: Engine Fuel Delivery Pressure
All Engines (2010 Emissions) -
Volvo All Engines (2004 Emissions) Fault Code: SID 211 FMI 4 Sensor Supply Voltage #2
All Engines (2004 Emissions)