This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Multiple lost flames
Probable cause
1) No spark
2) Aftertreatment ignition coil
3) Ignition wire connections
4) Aftertreatment fuel system
5) Aftertreatment Hydrocarbon Doser
6) Aftertreatment diesel particulate filter (DPF) combustion air valve
7) Aftertreatment diesel particulate filter (DPF) air supply
8) Aftertreatment Diesel Particulate Filter (DPF) Air shutoff Valve Solenoid
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P100711 PID: EMS Air Filter Indicator
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 171 FMI 12 PID: 171 Ambient Air Temperature
All Engines (2010 Emissions) -
Volvo All Engines (2004 Emissions) Fault Code: SID 4 FMI 12 Fuel Injector Unit #4
All Engines (2004 Emissions) -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3719 FMI 16 (ACM) Soot Level High
DD13 GHG14 (2014-16) -
Volvo All Engines (2017 Emissions) Fault Code: P208B00 PID: ACM Reductant Pump “A” Control Performance/Stuck Off
All Engines (2017 Emissions)