This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Multiple lost flames
Probable cause
1) No spark
2) Aftertreatment ignition coil
3) Ignition wire connections
4) Aftertreatment fuel system
5) Aftertreatment Hydrocarbon Doser
6) Aftertreatment diesel particulate filter (DPF) combustion air valve
7) Aftertreatment diesel particulate filter (DPF) air supply
8) Aftertreatment Diesel Particulate Filter (DPF) Air shutoff Valve Solenoid
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2010 Emissions) Fault Code: SPN 153 FMI 7 PID: PSID 23 Engine High Resolution Crankcase Pressure
All Engines (2010 Emissions) -
Volvo All Engines (2004 Emissions) Fault Code: PID 98 FMI 4 Engine Oil Level / Temperature Sensor
All Engines (2004 Emissions) -
PACCAR MX (2004 Emissions) Fault Code: P1306 Cylinder 4 – Intermittent Misfire
MX (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P24B100 PID: EMS Particulate Matter Sensor Circuit High
All Engines (2013 Emissions) -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00