The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
2) Aftertreatment selective catalytic reduction (SCR) catalyst warming not possible
Probable cause
1) Connector
2) Short circuit to voltage supply, Control wire (+)
3) Engine wiring harness
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P20A013 PID: ACM Reductant Purge Control Valve
All Engines (2013 Emissions) -
Allison 3000 & 4000 Gen 4 Fault Code: P0731 Incorrect 1st Gear Ratio
3000 & 4000 Gen 4 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 636 FMI 14 (MCM) Swapped Pins
DD15 GHG14 (2014-16)