The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
2) Aftertreatment selective catalytic reduction (SCR) catalyst warming not possible
Probable cause
1) Connector
2) Short circuit to voltage supply, Control wire (+)
3) Engine wiring harness
4) Engine control module (ECM)
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 190 FMI 0 (MCM) Engine Over Speed
DD15 EPA07 (2007-09) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 633 FMI 3 PID: SID 18 Engine Fuel Actuator 1 Control Command
All Engines (2010 Emissions) -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 100 FMI 1 (MCM) Low Engine Oil Pressure
DD13 EPA07 (2007-09)