The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
2) Aftertreatment selective catalytic reduction (SCR) catalyst warming not possible
Probable cause
1) Connector
2) Short circuit to voltage supply, Control wire (+)
3) Engine wiring harness
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5
-
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 713 FMI 4 (CPC) Short to Ground Circuit
DD16 EPA07 (2007-09) -
Volvo All Engines (2017 Emissions) Fault Code: P05E362 PID: EMS Park Brake Sensor/Switch Circuit
All Engines (2017 Emissions) -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 168 FMI 18 (CPC) Battery Voltage Low
DD16 GHG14 (2014-16) -
Volvo All Engines (2004 Emissions) Fault Code: PPID 35 FMI 4 EGR Mass Flow Sensor
All Engines (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P060100 PID: EMS Internal Control Module Memory Check Sum Error
All Engines (2013 Emissions)