This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Regeneration failed to start, Multiple occurrences
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Ignition wire connections
2) Nozzle
3) Aftertreatment diesel particulate filter (DPF) Ignition electrode(s)
4) Aftertreatment Fuel Supply Pressure
5) Aftertreatment fuel shut-off valve
6) Flame temperature sensor
7) Aftertreatment ignition coil
8) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
9) Low turbocharger boost
10) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
11) Aftertreatment Control Module (ACM)
-
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5 -
JPRO 2022 v1 Commercial Vehicle Diagnostics V1 Software Download & Installation Service ( 1 PC )
JPRO $94.00Rated 0 out of 5 -
Scania SDP3 2.48.6 Diagnosis & Programming for VCI 3 VCI3 without Dongle
Scania $30.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2685 Actuator Supply Circuit Voltage 3 Low (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2671 Actuator Supply Voltage 2 (HSD2) – High (Batt)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2723 Pressure Control Solenoid 1 (PCS1) – Stuck Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2730 Pressure Control Solenoid 1 (PCS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0974 Shift Solenoid 1 (SS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2729 Pressure Control Solenoid 1 (PCS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2641 Torque Management Feedback Signal – LRTP
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5
-
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 2791 FMI 16 (MCM) Smart Remote Actuator 3 (EGR) , Learn Cycle Too Large
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 110 FMI 2 PID: Engine Coolant Temperature
All Engines (2010 Emissions)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P112200 PID: EMS EGR Temperature Moderately High
All Engines (2013 Emissions)Rated 0 out of 5 -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 625 FMI 9 (MCM) No Data Received from Engine CAN Link
DD15 EPA07 (2007-09)Rated 0 out of 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 641 FMI 0 PID: SID 27 Engine Variable Geometry Turbocharger (VGT) Actuator 1
All Engines (2010 Emissions)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P054500 PID: ACM Exhaust Gas Temperature Short Circuit Low
All Engines (2013 Emissions)Rated 0 out of 5 -
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 729 FMI 0 (MCM) Grid Heater Permanently On
DD16 EPA07 (2007-09)Rated 0 out of 5