The aftertreatment diesel particulate filter (DPF) atomization air pressure sensor is used to monitor the pressure of the compressed air supply to the aftertreatment DPF atomization module during active diagnostics and measures the combined atomization fuel and air pressure during burner operation. The sensor consists of a pressure sensitive diaphragm/amplifier sensor. Air pressure causes the sensors diaphragm to deflect and produce an electrical signal proportional to the pressure. The diaphragm deflection signal is amplified in the sensor.
Conditions for diagnostic trouble code (DTC):
1) Low air pressure check failed during active diagnostics check of the air bleed orifice on the aftertreatment diesel particulate filter (DPF) atomization module
Observable symptoms
1) Regeneration not possible
Probable cause
1) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Internal air bleed orifice)
2) Low air pressure
3) Aftertreatment DPF Atomization Air Pressure Sensor
-
Volvo PROSIS Offline 2019 Parts Catalog Installation Service
Trucks software $45.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2685 Actuator Supply Circuit Voltage 3 Low (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2724 Pressure Control Solenoid 1 (PCS1) – Stuck On
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0980 Shift Solenoid 3 (SS3) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0976 Shift Solenoid 2 (SS2) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0974 Shift Solenoid 1 (SS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5
-
Allison 1000 & 2000 Gen 5 Fault Code:P0734 Incorrect 4th Gear Ratio
1000 & 2000 Gen 5Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P249F92 PID: EMS Excessive Time To Enter Closed Loop DPF Regeneration Control
All Engines (2013 Emissions)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 4353 FMI 5 (ACM) Diffuser Heater Open Circuit
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 715 FMI 4 (CPC) Digital Output 4 12 Circuit Failed Low
DD15 EPA07 (2007-09)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P0183 Fuel Temperature – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A42)
MX (2004 Emissions)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3664 FMI 6 (MCM) Injector Cylinder #6 Amplifier Control Valve – Valve Shorted Circuit
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2723 Pressure Control Solenoid 1 (PCS1) – Stuck Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Eaton Fuller Advantage (2017) Fault Code: 25 PID: SPN: 629 FMI: 1 No Faults Found: Data Valid But Below Normal
DTC TRUCKSRated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P054500 PID: ACM Exhaust Gas Temperature Short Circuit Low
All Engines (2017 Emissions)Rated 0 out of 5