The aftertreatment diesel particulate filter (DPF) atomization air pressure sensor is used to monitor the pressure of the compressed air supply to the aftertreatment DPF atomization module during active diagnostics and measures the combined atomization fuel and air pressure during burner operation. The sensor consists of a pressure sensitive diaphragm/amplifier sensor. Air pressure causes the sensors diaphragm to deflect and produce an electrical signal proportional to the pressure. The diaphragm deflection signal is amplified in the sensor.
Conditions for diagnostic trouble code (DTC):
1) Atomization air pressure above normal value with aftertreatment diesel particulate filter (DPF) air shutoff valve closed and aftertreatment DPF atomization air valve open during active diagnostics
Observable symptoms
1) Regeneration not possible
Probable cause
1) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Diesel Particulate Filter (DPF) Air shutoff Valve)
2) Aftertreatment DPF Atomization Air Pressure Sensor
3) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Aftertreatment DPF Atomization Air Actuator)
-
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5 -
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P0973 Shift Solenoid 1 (SS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0976 Shift Solenoid 2 (SS2) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2670 Actuator Supply Voltage 2 (HSD2) – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0979 Shift Solenoid 3 (SS3) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2723 Pressure Control Solenoid 1 (PCS1) – Stuck Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5
-
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3464 FMI 14 (MCM) Intake Air Throttle Control Electrical Fault
DD16 EPA07 (2007-09)Rated 0 out of 5 -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 636 FMI 8 (MCM) Crankshaft Position Sensor Time Out
DD16 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P066611 PID: EMS Control Module Internal Temperature Sensor “A”
All Engines (2013 Emissions)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P040371 PID: EMS EGR “A” Control
All Engines (2013 Emissions)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P1167 Fuel Temperature – Data Valid but Too High, Least Severe
MX (2004 Emissions)Rated 0 out of 5 -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3480 FMI 1 (MCM) Hydrocarbon Doser Fuel Supply Pressure Abnormal
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Allison WTEC II Fault Code: 13 PID: SPN: 13 FMI: ECU input voltage, medium low
AllisonRated 0 out of 5 -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 174 FMI 0 (MCM) Supply Fuel Temperature Sensor Too High
DD13 EPA07 (2007-09)Rated 0 out of 5 -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3363 FMI 1 (ACM) Diesel Exhaust Fluid Tank Temperature – Low
DD13 EPA10 (2010-13)Rated 0 out of 5