The aftertreatment diesel particulate filter (DPF) atomization air pressure sensor is used to monitor the pressure of the compressed air supply to the aftertreatment DPF atomization module during active diagnostics and measures the combined atomization fuel and air pressure during burner operation. The sensor consists of a pressure sensitive diaphragm/amplifier sensor. Air pressure causes the sensors diaphragm to deflect and produce an electrical signal proportional to the pressure. The diaphragm deflection signal is amplified in the sensor.
Conditions for diagnostic trouble code (DTC):
1) Atomization air pressure above normal value with aftertreatment diesel particulate filter (DPF) air shutoff valve closed and aftertreatment DPF atomization air valve open during active diagnostics
Observable symptoms
1) Regeneration not possible
Probable cause
1) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Diesel Particulate Filter (DPF) Air shutoff Valve)
2) Aftertreatment DPF Atomization Air Pressure Sensor
3) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Aftertreatment DPF Atomization Air Actuator)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5
-
Allison 1000 & 2000 Gen 5 Fault Code:P0732 Incorrect 2nd Gear Ratio
1000 & 2000 Gen 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 412 FMI 5 PID: Engine Exhaust Gas Recirculation Temperature
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P20C113 PID: ACM Reductant Heater “C” Control
All Engines (2013 Emissions)