The aftertreatment diesel particulate filter (DPF) combustion air valve is controlled by the aftertreatment control module (ACM) output. The combustion air valve is normally closed and is opened when a ground signal is supplied by the ACM to the combustion air valve solenoid. When opened, charged air from the intake manifold is supplied through the combustion air valve to the aftertreatment DPF combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:33 is above normal value
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
Probable cause
1) Short circuit to voltage supply, Control wire (-)
2) Connector
3) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
4) Chassis Harness
5) Aftertreatment DPF Combustion Air Solenoid
6) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5
-
Volvo All Engines (2004 Emissions) Fault Code: PID 252 FMI 9 Date Data Failure
All Engines (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P113F12 PID: EMS Buffered Idle Validation Switch Wire – VECU Side
All Engines (2013 Emissions) -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 2631 FMI 1 (MCM, ACM) Low Air Flow
DD15 EPA07 (2007-09) -
Volvo All Engines (2017 Emissions) Fault Code: P204A13 PID: EMS Reductant Pressure Sensor
All Engines (2017 Emissions)