The atomization air valve is part of the atomization module and the combustion air valve is located on the engine. Both are controlled by the same DPF ECU output. The valves are normally closed and are opened when voltage is supplied by the DPF ECU. When opened, compressed air supplied from the air tank through the priority valve is supplied through the atomization air valve to the atomization nozzle while charged air from the intake manifold is supplied through the combustion air valve to the DPF Unit combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A118.B:D3 is below normal value
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Wiring harness between Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve and Aftertreatment Control Module (ACM)
2) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
3) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
4) DPF Control Unit
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P011511 PID: EMS Engine Collant Temperature Sensor 1
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P255601 PID: EMS Engine Coolant Level Sensor/Switch
All Engines (2013 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 3226 FMI 2 PID: PSID 90 Aftertreatment Outlet NOx
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P220B1C PID: EMS NOx Sensor Gas Outlet High Voltage
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P103200 PID: EMS Particulate Matter Sensor Removed From Exhaust
All Engines (2017 Emissions)