The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Output activated
Observable symptoms
1) Regeneration not possible
Probable cause
1) Connector
2) Engine wiring harness
3) Aftertreatment Hydrocarbon Dosing Module
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P056084 PID: ACM System Voltage
All Engines (2013 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 3511 FMI 4 PID: PSID 113 Sensor Supply Voltage 3
All Engines (2010 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P033531 PID: EMS Crankshaft Position Sensor “A”
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 174 FMI 3 PID: Cummins DTC
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P117411 PID: EMS Transmission Range Request
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P24D100 PID: EMS Particulate Matter Sensor Regeneration Incomplete
All Engines (2013 Emissions)