This Diagnostic Trouble Code (DTC) monitors and evaluates malfunctions in the (EGR) Exhaust Gas Recirculation Diff Pressure. A faulty (EGR) Exhaust Gas Recirculation differential Pressure can lead to uneven running and response problems.
Conditions for diagnostic trouble code (DTC):
1) Abnormal sensor signal
Observable symptoms
1) Exhaust leakage
Probable cause
1) Wiring harness
2) Clogged ports
3) EGR Cooler
4) EGR system pipe and connections
5) EGR differential pressure sensor
Detailed information
Activation
1) The diagnostic trouble code (DTC) is first set after 30?min when driving with varying engine loads
2) At idle the diagnostic trouble code (DTC) is normally not set to active
3) Diagnostic trouble codes (DTCs) are stored for 400 days counted from the first DTC setting occurrence
Deactivation
1) The diagnostic trouble code (DTC) will be shown as inactive when the ignition key is turned to the 0 position
2) To fully verify the repair it may be necessary to activate vehicle functions or perform a test drive
-
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5
Related products
-
Volvo All Engines (2010 Emissions) Fault Code: SPN 102 FMI 12 PID: Engine Intake Manifold
All Engines (2010 Emissions)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 168 FMI 1 (ACM) Battery Voltage Low
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P101200 PID: EMS Cold Start Cylinder 1 Fuel Injector Offset Learning at Min Limit
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 4258 FMI 4 (MCM) Injector Amplifier Control Valve Cylinder 4, 5, 6 Shorted to Ground
DD15 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 4335 FMI 4 (ACM) Diesel Exhaust Fluid Metering Unit Air Pressure Sensor Circuit Failed Low
DD15 EPA10 (2010-13)Rated 0 out of 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 1265 FMI 5 PID: SID 85 Engine Piston Cooling Oil Pressure Actuator
All Engines (2010 Emissions)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 615 FMI 4 (MCM) Axial Power Turbine Air Seal Pressure Regulator Valve Circuit Failed High
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 4374 FMI 1 PID: PSID 87 Aftertreatment 1 SCR Catalyst Reagent Pump Motor Speed
All Engines (2010 Emissions)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P1687 Starter Motor – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (B16)
MX (2004 Emissions)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P054013 PID: EMS Intake Air Heater “A” Control
All Engines (2017 Emissions)Rated 0 out of 5