Volvo All Engines (2010 Emissions) Fault Code: SPN 4334 FMI 2 PID: PPID 273 Aftertreatment 1 SCR Dosing Reagent Absolute Pressure
The aftertreatment control module (ACM) uses the aftertreatment diesel exhaust fluid (DEF) dosing pressure sensor value to adjust and maintain DEF pressure at the DEF dosing valve by controlling DEF pump speed. If the pressure decreases below expected value when the pump is in initial pressure build-up mode or if the pressure increases above expected value when pump is in idle speed mode, the ACM considers DEF pressure outside of normal operating range and indicates a malfunction in a DEF dosing pressure sensor.
Conditions for diagnostic trouble code (DTC):
1) Abnormal value
Probable cause
1) Hose
2) Pressure sensor
3) Aftertreatment diesel exhaust fluid (DEF) pump, Internal fault
-
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
CLAAS WebTIC Offline [11.2021] Service Information – ENGLISH Language
CLAAS $100.00Rated 0 out of 5 -
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2669 Actuator Supply Voltage 2 Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2671 Actuator Supply Voltage 2 (HSD2) – High (Batt)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1891 Throttle Position Sensor (TPS) PWM Signal – Low Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097B Shift Solenoid 2 (SS2) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2670 Actuator Supply Voltage 2 (HSD2) – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5
-
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 164 FMI 4 (MCM) Fuel Rail Pressure Sensor Circuit Failed Low (Short to Ground)
DD15 EPA07 (2007-09)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: U300A12 PID: ACM Key Position
All Engines (2013 Emissions)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P033638 PID: EMS Crankshaft Position Sensor “A” Circuit Range/Performance
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 4076 FMI 4 (MCM) Engine Coolant Inlet Temperature Circuit Failed Low
DD15 EPA07 (2007-09)Rated 0 out of 5 -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1636 FMI 20 (MCM) Intake Manifold Temperature Drift (Low Box)
DD16 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3512 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P2A1214 PID: EMS Injection Pump Fuel Metering Control “C” (Cam/Rotor/Injector)
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 641 FMI 4 (MCM) Turbocharger Control Circuit Failed Low
DD16 EPA07 (2007-09)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P20E997 PID: ACM Reductant Pressure Too High
All Engines (2017 Emissions)Rated 0 out of 5