Volvo All Engines (2010 Emissions) Fault Code: SPN 641 FMI 4 PID: SID 27 Engine Variable Geometry Turbocharger (VGT) Actuator 1
The (VGT) Variable Geometry Turbocharger Actuator is a self-contained component with motors, sensors and a control unit.
The (VGT) Variable Geometry Turbocharger uses a movable nozzle to adjust the intake manifold pressure for various operating conditions. Nozzle movement is controlled by an actuator mounted on the tubocharger. When the Engine Control Module (ECM) Relay is energized, a fuse supplies battery voltage to the (VGT) Variable Geometry Turbocharger and the unit is grounded by means of the engine block.
Conditions for diagnostic trouble code (DTC):
1) Actuator voltage is less than 10 volts for 10 continuous seconds
Observable symptoms
1) Low Power
2) Regeneration not possible
Probable cause
1) Software
2) Voltage supply interrupted
3) Poor ground connection
4) Actuator
Related products
-
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 986 FMI 9 (CPC) CM1 Message is Missing
DD13 GHG14 (2014-16) -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Volvo All Engines (2017 Emissions) Fault Code: P268F00 PID: EMS Cylinder 4 Injector Data Incompatible
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 3241 FMI 5 PID: Aftertreatment 1 Exhaust Gas Temperature 1
All Engines (2010 Emissions) -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 98 FMI 18 (CPC) Low Engine Oil Level
DD13 EPA10 (2010-13) -
Volvo All Engines (2004 Emissions) Fault Code: SID 6 FMI 12 Fuel Injector Unit #6
All Engines (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P241E00 PID: ACM Reductant Heater Coolant Control Valve Stuck Closed
All Engines (2013 Emissions)