Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID211 FMI 3 Sensor Supply Voltage #2 (+5V DC)
Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID211 FMI 3 Sensor Supply Voltage #2 (+5V DC)
DETECTION CONDITIONS:
The engine control unit (E-ECU) registers that the voltage is above 5.5 V. (EB17)
SYMPTOM:
1. Incorrect values from engine’s sensors generated.
2. Low power.
POSSIBLE CAUSES:
Short-circuit to battery voltage on the output.
-