Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID230 FMI 5 Idle Validation Switch
Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID230 FMI 5 Idle Validation Switch
DETECTION CONDITIONS:
The engine control unit (E-ECU) registers current too low. (EB15)
SYMPTOM:
Limp home mode not functioning.
POSSIBLE CAUSES:
1. Short circuit to lower voltage.
2. Open circuit.
-