Cummins ISB4.5 CM2150 Fault Code: 477 PID: 444 SPN: 444 FMI: 1 Battery 2 Voltage – Data Valid but Below Normal Operating Range – Moderately Severe Level.
Circuit Description
The aftertreatment diesel exhaust fluid controller communicates with the ECM and controls the heating, dosing, and purging of the aftertreatment diesel exhaust fluid system.
Component Location
The aftertreatment diesel exhaust fluid controller is installed on the vehicle by the OEM. Refer to the OEM Service Manual for component location.
Conditions for Running the Diagnostics
This diagnostic runs continuously when the keyswitch is in the ON position.
Conditions for Setting the Fault Codes
The aftertreatment diesel exhaust fluid controller detects that the battery supply voltage is lower than a threshold.
Action Taken When the Fault Code is Active
-The ECM illuminates the amber CHECK ENGINE lamp or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code
-The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes
-The ECM will turn off the MIL after 3 consecutive trips where the diagnostic runs and passes.
Possible Causes
-Improper battery voltage setting in INSITE™ electronic service tool
-A damaged alternator causing low voltage
-A weak or damaged battery.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00