Cummins ISC CM2150 (2007-09) Fault Code: 2274 PID: 411 SPN: 411 FMI: 4 Exhaust Gas Recirculation Valve Delta Pressure Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the EGR differential pressure sensor circuit.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
Possible causes:
1)A signal circuit open or shorted to ground in the engine harness or sensor
2)A supply wire open or shorted to ground
3)A malfunctioning EGR differential pressure sensor.
Possible repairs:
1)Replace the ECM.
2)Replace the EGR valve delta pressure sensor.
3)Replace the engine harness. Refer to Procedure 019-043 (Engine Wiring Harness) in Section 19.
4)Repair the OEM harness
Categories Cumminz, DTC TRUCKS, ISC CM2150 (2007-09)
Tags 2007-09, at, Below, Circuit, Circuit., CM2150, Code2274, Cummins, Delta, Detected, Differential, EGR, Exhaust, Fault, FMI4, Gas, ISC, Low, Normal, or, PID411, Pressure, Recirculation, Sensor, Shorted, signal, Source, SPN411, the, to, Valve, Voltage
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00