Cummins ISC CM2150 (2007-09) Fault Code: 2351 PID: SID 146 SPN: 2791 FMI: 4 EGR Valve Control Circuit – Voltage Below Normal or Shorted to Low Source. Motor terminal or motor coil short circuit to ground or power supply has been detected by the ECM.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe™ Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
Possible causes:
1)EGR motor circuit shorted to ground
2)EGR motor circuit shorted to battery supply.
Possible repairs:
1)Repair or replace the engine harness.
2)Replace the EGR valve motor.
3)Replace the ECM.
Categories Cumminz, DTC TRUCKS, ISC CM2150 (2007-09)
Tags 146, 2007-09, been, Below, by, Circuit, CM2150, Code2351, coil, Control, Cummins, Detected, ECM., EGR, Fault, FMI4, ground, has, ISC, Low, Motor, Normal, or, PIDSID, power, short, Shorted, Source, SPN2791, Supply, terminal, the, to, Valve, Voltage
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00