Cummins ISC CM2150 (2007-09) Fault Code: 386 PID: SID 212 SPN: 3509 FMI: 3 Sensor Supply 1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 1 circuit.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
Low voltage on the +5 volt supply wire can be caused by a short circuit to ground in a supply wire, a short circuit between a supply wire and a return wire, a failed sensor, or a failed ECM power supply.
Possible repairs:
1)Repair or replace the engine harness.
2)Replace the ECM.