Cummins ISX CM870 (2003-06) Fault Code: 338 PID: S087 SPN: 1267 FMI: 3/3 Idle Shutdown Vehicle Accessories Relay Driver Circuit – Voltage Above Normal, or Shorted to High Source. Open circuit or short to voltage source detected at the idle shutdown vehicle accessory/ignition bus relay circuit.
The ECM monitors the voltage level on this circuit. If it detects a voltage when the signal is commanded OFF, it records this fault code.
Possible causes:
1)ECM Idle Shutdown feature set up incorrectly.
2)Open circuit in the idle shutdown relay, OEM harness, or connectors.
3)Short circuit to a voltage source in the OEM harness or relay.
Possible repair:
1)Replace the idle shutdown relay.
2)Repair or replace the OEM harness.
Categories Cumminz, DTC TRUCKS, ISX CM870 (2003-06)
Tags -, 1267, 2003-06, 3/3, 338, Above, Accessories, accessory/ignition, at, bus, Circuit, Circuit., CM870, Code, Cummins, Detected, Driver, Fault, FMI, High, Idle, ISX, Normal, Open, or, PID, Relay, S087, short, Shorted, Shutdown, Source, Source., SPN, the, to, Vehicle, Voltage
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0848 Transmission Pressure Switch Solenoid D Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00