Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3223 FMI 7 (ACM) NOx RAW Sensor Not Ready After Dewpoint Enable Check
DESCRIPTION:
NOx inlet sensor failure to active.
MONITORED PARAMETER:
NOx inlet sensor.
TYPICAL ENABLING CONDITIONS:
NOx raw count.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Always on
DASH LAMPS:
MIL
ENGINE REACTION:
None
VERIFICATION:
Once engine is at standard operating temperature, drive at highway speed with loaded trailer above 1130 rpm continuously for twenty minutes.
NOTE: If codes 5357-16 or 5357-18 present, fix those first.
PROBABLE CAUSES:
1. Perform a stationary regen.
2. SCR inlet NOx sensor.